5604-RIO-PDPMV1

Rockwell Automation Remote I/O to PROFIBUS DPV1 Master Gateway, non-CE

5604-RIO-PDPMV1

Discontinued: No new product for sale. More Info

The ProLinx® family Allen Bradley Remote I/O Adapter to PROFIBUS DPV1 Master communications module (5604-RIO-PDPMV1) creates a powerful connection between devices on a Remote I/O network and PROFIBUS slave devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Remote I/O port and a PROFIBUS DPV1 Master with a RS-485 9-pin D shell female connector interface with isolated Opto-Couplers.

The RIO interface is an adapter (slave) which can be connected to a RIO scanner (master) that controls the data transfer.

The PROFIBUS DPV1 Master (PDPMV1) protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. The DPV1 master supports FDT/DTM communication when using the PSW-cDTM-PDPM FDT communication DTM. The PROFIBUS DPV1 Master FDT communication DTM software is an interface between any compliant FDT software container, an FDT device DTM and applicable PROFIBUS slave devices.

The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in the industrial automation today.

特性 优势

Applications

Allows for legacy Allen-Bradley 1771 PLC5 controllers with native Remote I/O communication ports to act as PROFIBUS DPV1 Masters on a PROFIBUS network.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18-32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (without condensation)

Dimensions

Standard
5.20 in H x 2.07 in W x 4.52 in D
13.2 cm x 5.25 cm x 11.48 cm

Extended
5.20 in H x 2.73 in W x 4.52 in D
13.2 cm x 6.934 cm x 11.48 cm

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

Mini-DIN
RS-232 only
No hardware handshaking

Ethernet Port

10Base-T Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

RIO Connector

3 pos screw-terminal adaptor(J803)

RIO LED Indicators

Active - Green

PROFIBUS Connector

DB-9F Standard PROFIBUS connector and isolated Opto-Couplers

PROFIBUS LED Indicators

Master, Run, Error and Token LED Indicators

Shipped with each unit

1 each, Mini-DIN to DB-9M cable per serial port
1 each, RS232-to-RS422/RS485 Screw Terminal Adapter per serial port
4 ft RS-232 configuration cable
 
2.5mm screwdriver
CD (documentation and Configuration utility)

下载

LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13
RIO PDPMV1 Datasheet 315.66 kB 最后修改 2023.11.23
RIO Protocol Manual 571.18 kB 最后修改 2012.02.10
PDPMV1 Protocol Manual 3.23 MB 最后修改 2023.02.02
RIO-PDPMV1 Setup Guide 733.17 kB 最后修改 2010.05.10
RIO-PDPMV1 Sample Ladder 96.00 kB 最后修改 2010.05.10
RIO-PDPMV1 Sample Configuration File 27.21 kB 最后修改 2010.05.10

协议

PDPMV1 Protocol Specification


The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.

The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.

  • Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB)
  • Project-unique GSD file import library
  • Monitoring and Modification of process data and DPV1 acyclic data
  • Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices
  • Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network
  • Automatic project documentation
  • Automatic Bus Parameter calculation
  • Online slave diagnostics
  • Supports all standardized baud rates, up to 12Mbps
  • Supports extended diagnostic data (DPV1)
  • Auto baud detection at all valid PROFIBUS DPV1 rates
  • Multiple modules can be placed in a single rack
  • CRC checksum determination of slave configuration consistency to processor
  • Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold
  • FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM)

PROFIBUS Master Specifications

  • Up to 125 Slaves can be connected with a repeater
  • Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data
  • Supports Extended Diagnostic Data
  • RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter
  • Acyclic communications (DPV1), Read and Write
  • Alarm Handling (DPV1)
  • Supports Sync and Freeze commands
  • Supports PROFIdrive 3.1 compliant parameter read and write operations
  • Supports Multicast and Broadcast telegrams (DPV1)

PROFIBUS Master Port

  • DB-9F Optically Isolated RS-485
  • Ready, Run, Error and Token LED Indicators
  • PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers

Protocol Specifications

The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.


RIO Protocol Specification


The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.


Protocol Specifications

The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.

Software Configurable Parameters

Rack Number Addressing

0 to 63

Rack Size

¼-rack, ½-rack, ¾-rack and full rack

Starting Group

0,2,4,6

Last Rack

Yes or No

Baud Rate

57.6K, 115K, 230K

Functional Specifications

Supports block-transfers of data with scanner

Supports I/O data movement. Amount determined by rack size configuration

BTW Command - up to 64 words

BTR Command - up to 63 words

Physical Connection

Remote I/O connector

Standard 3-screw termination connector


证书

ATEX Letter of Conformity 114.27 kB 最后修改 2022.05.12
CB Safety 35.78 kB 最后修改 2022.04.27
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16