Discontinued: No new product for sale. More Info

The ProLinx DH-485 to HART Multi-drop Gateway creates a powerful connection between devices on a DH-485 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and up to eight configurable HART Multi-drop channels.

The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. User configurable data mapping make the interface an easy to use and powerful data transfer tool.

The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.

特性 优势

Applications

The DH485-HART modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate HART Multi-drop devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing .

应用程序

The DH485-HART modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate HART Multi-drop devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (without condensation)

Dimensions

Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)

Extended:
 5.20 in H x 2.73 in W x 4.52 in D (13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
HART Channel Activity (Green)

(Ethernet-equiped Gateways Only)
Ethernet Link
Ethernet Activity

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

RJ45 Connector

Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

HART Interface

Four (4) HART Multi-drop channels

Screw terminals for each channel

24 VDC power supply
(third-party, not supplied with the gateway)

Must have sufficient current capacity to supply all loop-powered HART devices

Screw terminals for 24 VDC available on HART connector, supplied with the gateway, for loop-powered configurations

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5 mm screwdriver
CD (docs and Configuration utility)
RS232-to-RS422/RS485 Screw Terminal Adapter(s) (Serial Gateways Only)
HART Terminal Block connector

下载

ProSoft Configuration Builder (PCB)
DH485 HART Datasheet 61.72 kB 最后修改 2014.11.08
DH485 Driver Manual 1.11 MB 最后修改 2009.12.10
HART Driver Manual 922.47 kB 最后修改 2017.09.15

协议

HART Protocol Specification


The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.


Protocol Specifications

The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters

Communication parameters

Number of HART Preambles: 2 to 50

Enable Handheld: Y or N

Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable, Short / Long Address Retries, Retries After Error

Poll Time After Error, Number of Commands, Slave List Error Pointer

HART Driver

Command List

Up to 100 fully configurable commands per channel

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

HART® is a registered trademark of the HART Communication Foundation


DH485 Protocol Specification


The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. User configurable data mapping make the interface an easy to use and powerful data transfer tool.


Protocol Specifications

The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.

General Protocol Information

Error Checking

BCC and CRC

Communication Parameters

Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud
Port 1 Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds

DH-485 Slave Mode

In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.

DH-485 Master Mode

In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

DH485 Functioning as a Master

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

Polling of command list

User configurable polling of commands, including disabled, continuous and on change of data (write only)


证书

CB Safety 35.78 kB 最后修改 2012.08.27
CE Mark 92.34 kB 最后修改 2013.02.28
Russian GOST-R 7.07 MB 最后修改 2013.02.22
GOST-R Declaration of Conformity 6.68 MB 最后修改 2013.02.22
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2013.07.02
UL/cUL; Class 1, Div 2 (Canada) 1.10 MB 最后修改 2013.07.02