The ProLinx Modbus TCP/IP to BACnet/IP Client Gateway creates a powerful connection between devices on a Modbus TCP/IP network and BACNET devices. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port.
The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.
The ProLinx BACnet/IP (Building Automation and Control networking) protocol version is designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, and air-conditioning control, lighting control, access control, and fire detection systems with limited BACnet/IP command support.
Powerful network integration |
|
Modbus TCP/IP protocol interface |
|
BACnet/IP Client |
|
Easy to Configure and Monitor |
|
Backed by ProSoft Technology |
|
The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
MNET BACNET Datasheet | 777.98 kB | 最后修改 2010.04.26 |
MNET Protocol Manual | 631.11 kB | 最后修改 2012.02.16 |
BACNET Protocol Manual | 742.83 kB | 最后修改 2012.02.16 |
PLX EDS File | 333.95 kB | 最后修改 2010.05.10 |
The BACnet/IP (Building Automation and Control networking) protocol is designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, and air-conditioning control, lighting control, access control, and fire detection systems. The ProLinx BACNET driver implements a subset of the BACnet/IP protocol.
BACnet/IP Client Specifications
The module controls the read/write data transfer between the gateway and other BACnet/IP devices.
BACnet/IP Client Specifications |
|
General | One client |
Command List | Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. |
Service Port | 1 to 65535 |
Function Code | 12, 14, 15 and 16 (Read/Write Single & Multiple) |
Data Type | 0, 1, 3 and 4 (BO, BI, AO & AI) |
Point Count | 1 to 25 |
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server |
|
General | Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000. |
Configurable Parameters |
Module IP Address |
Modbus TCP/IP Client |
|
General | Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) |
Configurable parameters | Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer |
Command List | Up to 100 fully configurable commands on the Client port |
Ex Certificate (ATEX Directive) | 114.27 kB | 最后修改 2013.11.11 |
CB Safety | 35.78 kB | 最后修改 2012.08.27 |
Declaration of Conformity (RoHS/CE) | 299.92 kB | 最后修改 2018.03.04 |
Russian GOST-R | 7.07 MB | 最后修改 2013.02.22 |
GOST-R Declaration of Conformity | 6.68 MB | 最后修改 2013.02.22 |
Korean KC Registration | 807.00 kB | 最后修改 2013.02.22 |
UL/cUL; Class 1, Div 2 | 1.08 MB | 最后修改 2013.07.02 |