5210-Ethernet-RIO

Modbus TCP/IP to Rockwell Automation Remote I/O Gateway

5210-MNET-RIO

Discontinued: No new product for sale. More Info

The ProLinx Modbus TCP/IP to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port.

The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.

The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.

特性 优势

Applications

The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

应用程序

The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

下载

MNET RIO Datasheet 68.11 kB 最后修改 2010.04.26
MNET Protocol Manual 631.11 kB 最后修改 2012.02.16
RIO Protocol Manual 571.18 kB 最后修改 2012.02.10
Prlxrio Sample Ladder 257.05 kB 最后修改 2008.09.03
ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13

协议

RIO Protocol Specification


The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.


Protocol Specifications

The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.

Software Configurable Parameters

Rack Number Addressing

0 to 63

Rack Size

¼-rack, ½-rack, ¾-rack and full rack

Starting Group

0,2,4,6

Last Rack

Yes or No

Baud Rate

57.6K, 115K, 230K

Functional Specifications

Supports block-transfers of data with scanner

Supports I/O data movement. Amount determined by rack size configuration

BTW Command - up to 64 words

BTR Command - up to 63 words

Physical Connection

Remote I/O connector

Standard 3-screw termination connector


MNET Protocol Specification


The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.


Protocol Specifications

The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.

Modbus TCP/IP Server

General

Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.

Configurable Parameters

Module IP Address
Modbus address offsetting

Modbus TCP/IP Client

General

Actively reads and writes data with Modbus TCP/IP compatible devices.

One client connection (up to 100 servers/devices with 100 commands)

Configurable parameters

Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer

Command List

Up to 100 fully configurable commands on the Client port


证书

ATEX Letter of Conformity 114.27 kB 最后修改 2022.05.12
CB Safety 35.78 kB 最后修改 2022.04.27
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16