5102-Serial

Modbus Master/Slave to DF1 Master/Slave Gateway

5102-MCM4-DFCM4

Discontinued: No new product for sale. More Info

The ProLinx Modbus Master/Slave to DF1 Master/Slave Gateway creates a powerful connection between Modbus Master/Slave and DF1 Master/Slave networks and devices. This stand-alone DIN-rail mounted protocol gateway provides four serial ports, each individually configurable as a Modbus or DF1 Master or Slave.

The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.

特性 优势

Product Applications

This module is fully configurable, allowing any of its four serial ports to be configured as either a Master or Slave utilizing either the DF1 or Modbus Protocols. This provides a great deal of application flexibility as the module can be used as a data concentrator (when configuring all four ports for the same protocol) or the module database can be shared between the DF1 and Modbus networks to allow the module to work as a bridge between the two different protocols. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

下载

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13
MCM DFCM Datasheet 107.61 kB 最后修改 2010.04.26
MCM Driver Manual 835.78 kB 最后修改 2009.12.10
DFCM Protocol Manual 866.04 kB 最后修改 2012.02.16

协议

DFCM Protocol Specification


The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.


Protocol Specifications

The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).

General Parameters

Communication parameters

Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud
Stop Bits: 1
Data Size: 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds

Error Checking

BCC and CRC

Miscellaneous

Full hardware handshaking control, providing radio, smart modem and multi-drop support
Floating point data supported

DF1 Master Protocol Specifications

The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.

DF1 Master Driver

DF1 Modes

Full-Duplex - Master (Module generates commands)

Half-Duplex - Polling

Command List

Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count

Polling of Command List

User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

DF1 Slave Protocol Specifications

The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.

DF1 Slave Driver

DF1 Modes

Full Duplex - Slave (not peer mode)
Half Duplex - Polled

Configurable parameters per slave port

Data Table File Start (File N[x] 0 to 999)
Data Table File Size (1 to 1000 words)
Data Table location in database (0 to 3999)


MCM Protocol Specification


The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.


Protocol Specifications

The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

General Parameters - Modbus Protocol

Communication parameters

Baud Rate: 110 to 115K baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds

Error Checking

RTU mode (binary) with CRC-16
ASCII mode with LRC error checking

Floating Point

Floating point data movement supported, including configurable support for Enron implementation

Function Codes

1: Read Output Status
2: Read Input Status
3: Read Multiple Data Registers
4: Read Input Registers
5: Write Single Bit
6: Write Single Data Register
15: Write Multiple Bits
16: Write Multiple Data Register

Modbus Master

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

Polling of command list

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Node address

1 to 247 (software selectable)


证书

CB Safety 35.78 kB 最后修改 2022.04.27
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16