The PS69-DPS module expands the functionality of Rockwell Automation’s CompactLogix™ to include PROFIBUS DP V0/V1. The PS69-DPS is a more cost-effective option offering more features than the MVI69-PDPS, and supports both I/O control and messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and acyclic messaging.
The PS69-DPS interface appears to the CompactLogix controller as a standard I/O module allowing it to be configured via RSLogix™ 5000, or configuration can be transferred from the Master to the PS69-DPS. For third party configuration a GSD file is supplied. The slave interface provides a diagnostic interface and has rotary switches for setting of the bus address. Complete program examples for simple and quick start-up are available.
Each module is equipped with LEDs to display communication and device status.
Features |
Benefits |
PROFIBUS Certified |
Recognized quality certification mark |
DPV1 supported |
Provides for acyclic messaging, extended diagnostics and extended data support |
Ladder logic module configuration |
Better Rockwell Automation® integration using ladder logic software |
The GSD file supplied is sufficient to integrate the PS69-DPS as a PROFIBUS DP Slave into the configuration of any PROFIBUS Master. The PROFIBUS address is set by rotary switches. The slave configuration can be either transferred from the Master to the PS69-DPS or can be defined from the Logix application.
Specification |
Description |
Processor |
EC1-160P with integrated ASPC2 |
PROFIBUS Interface |
RS-485, max. 12 Mbps, potential free, according EN 50170 |
Diagnostic Interface |
RS-232, PS/2 Mini-DIN female connector, 9600 Baud, non isolated |
Power Supply |
260 mA at +5 V ±5 % |
Power Supply Distance Rating |
6 |
Dimensions |
Standard 1769 Single-slot module |
Burst |
EN 61000-4-4, 2 kV, 5 kHz |
Surge |
EN 61000-4-5, 2 kV common mode, 1 kV differential mode |
ESD |
EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
Radiated/ Conducted Immunity |
EN 61000-4-3, 10 V/m, 30 to 1000 MHz, 80% AM, 1 kHz sinewave EN 61000-4-6, 10 V, 0.15 to 30 MHz |
Radiated/ Conducted Emission |
EN 55011 Class A |
Vibration/Shock |
IEC 600068-2-6, 10 to 150 Hz, IEC 600068-2-27, 15 g, 11 ms |
Operating Temp. |
32° F to 140° F (0° C to 60° C) |
Relative Humidity |
5% to 95% (without condensation) |
Agency Certification |
C-UL certified, UL 508 listed, CE |
PROFIBUS conformance |
PNO certified |
Specification |
Description |
Master |
According to IEC 61158 |
Slaves |
max. 125 with the use of separate repeaters. 32 devices allowed per segment with up to 4 segments |
Input Data |
max. 408 Bytes (*) |
Output data |
max. 480 Bytes (*) |
DPV0/V1 services |
Fail Safe Mode, Global Control, Sync and Freeze, Watchdog, Read Request, Write Request, Alarm and Extended Diagnostics |
Configuration Software |
· FDT software creates Generic DTMs from the GSD file· Monitoring and Modification of process data· Online slave diagnostics |
FDT/DTM Support |
PROSOFT.fdt FDT software included along with a master and network configuration DTM. The DTM acts as a communication DTM for networked slave devices. |
(*) Can differ on different type of CompactLogix™ Controller and depends on total amount of I/O data of a CompactLogix System.The maximum length of a bus segment depends on the baud rate used. Only PROFIBUS certified cable, preferably the cable type A, should be used.
ATEX Letter of Conformity | 83.59 kB | 最后修改 2022.05.12 |
CB Safety | 347.28 kB | 最后修改 2020.02.26 |
CE Mark | 91.88 kB | 最后修改 2013.02.22 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1.92 MB | 最后修改 2020.07.10 |
UL/cUL; Class 1, Div 2 | 1.12 MB | 最后修改 2019.02.27 |
UL/cUL; Class 1, Div 2 (Canada) | 1.14 MB | 最后修改 2019.02.27 |
Declaration of Conformity | 440.44 kB | 最后修改 2020.12.18 |
Declaration of REACH Compliance | 340.56 kB | 最后修改 2021.02.08 |