      MVI69-DFNT

      EtherNet/IP Client/Server Communication Module for CompactLogix

      MVI69-DFNT

      Limited Availability: Product with low inventory remaining. More Info

      The MVI69 EtherNet/IP (DF1 for Ethernet) Client/Server Communication Module is a CompactLogix / MicroLogix 1500 LRP backplane compatible module that allows CompactLogix / MicroLogix processors to interface easily with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. Devices commonly supporting the protocol include PLCs, PACs, and host HMI systems.

      The module can send read or write commands to remote devices on the EtherNet/IP network. The module also has 20 servers that allow the module to receive commands from
      remote devices. Up to 100 commands can be configured by the user. The Module provides support for an Ethernet port to be used in applications requiring a separate or dedicated network.

      A conformal coating option is available for this product.

      • 特性 优势
      • 规格
      • 硬件
      • 下载
      • 视频
      • 证书

      特性 优势

      The MVI69-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's CompactLogix processor and EtherNet/IP (DF1 for Ethernet) network applications. The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI69-DFNT also has 20 servers that allows the module to receive commands from remote devices. Up to 100 commands can be configured by the user.

      规格

      • Single Slot - 1769 backplane compatible
      • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
      • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
      • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.
      • Supports all CompactLogix processors: L20/L30/L31/L32/L35, L43 and L45 (L43 and L45 supported with RSLogix 5000 v16.03 or later)
      • Also supports MicroLogix 1500 LRP

      硬件

      Specification

      Description

      Dimensions

      Standard 1769 Single-slot module

      Current Load

      800 mA max @ 5 VDC
      Power supply distance rating of 2 (L43 and L45 installations on first 2 slots of 1769 bus)

      Operating Temp.

      32° F to 140° F (0° C to 60° C)

      Storage Temp.

      -40° F to 185° F (-40° C to 85° C)

      Relative Humidity

      5 to 95% (without condensation)

      LED Indicators

      Power and Module Status
      Application Status
      CFG Port Activity
      Ethernet Port Activity
      Error Status

      CFG Port (CFG)

      RJ45 (DB-9M with supplied cable)
      RS-232 only
      No hardware handshaking

      App Port (Ethernet modules)

      10/100 Base-T Ethernet compatible interface
      Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

      Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

      Shipped with Unit

      RJ45 to DB-9M cables for each port
      6-foot RS-232 configuration Cable

      下载

      MVI69-DFNT Datasheet 407.16 kB 最后修改 2019.06.13
      MVI69-DFNT User Manual 2.99 MB 最后修改 2014.05.14
      MVI69-DFNT Sample Ladder 175.56 kB 最后修改 2018.09.04
      MVI69-DFNT Configuration File 2.69 kB 最后修改 2010.05.19
      MVI69 EDS File 399 B 最后修改 2013.03.08
      WATTCP Ethernet Configuration 521 B 最后修改 2013.02.06
      Conformal Coating Option 2.14 MB 最后修改 2020.05.18
      LifeCycle Letter MVI69-DFNT_EGD_FLN_3964R 107.56 kB 最后修改 2024.02.16

      视频

      Understanding Client, Server & I/O Messaging for Ethernet Networks

      ProSoft Technology Products Overview

      download video

      证书

      ATEX Letter of Conformity 83.59 kB 最后修改 2022.05.12
      CB Safety 347.28 kB 最后修改 2020.02.26
      Declaration of Conformity (RoHS/CE) 531.65 kB 最后修改 2020.12.18
      Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
      Korean KC Registration 584.13 kB 最后修改 2020.03.13
      UL/cUL; Class 1, Div 2 (Canada) 1.14 MB 最后修改 2019.02.27
      UL/cUL; Class 1, Div 2 232.99 kB 最后修改 2019.04.08
      Declaration of REACH Compliance 340.56 kB 最后修改 2022.09.08