5605-RIO-PDPS

Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway

5605-RIO-PDPS

Discontinued: No new product for sale. More Info

The ProLinx Rockwell Automation Remote I/O Adapter to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Remote I/O network and a PROFIBUS master device. This stand-alone DINrail mounted protocol gateway provides one Remote I/O port and one PROFIBUS DP Slave configurable DB9F port.

The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.

The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.

特性 优势

Applications

The RIO-PDPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP master device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

应用程序

The RIO-PDPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP master device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

下载

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13
RIO PDPS Datasheet 132.23 kB 最后修改 2010.04.26
RIO Protocol Manual 571.18 kB 最后修改 2012.02.10
PDPS Driver Manual 684.88 kB 最后修改 2009.12.10
ProLinx GSD File 398.03 kB 最后修改 2010.05.11

协议

PDPS Protocol Specification


The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.


Protocol Specifications

The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.

General Parameters

GSD File

PRLX05A5.GSD

Downloadable from ProSoft Technology web site

PROFIBUS Specifications

Communication parameters

Baud Rate: 9.6 kbps to 12 Mbps

Supported I/O length

244 bytes Input data

244 bytes Output data

400 bytes total

Supported PROFIBUS DP features

PROFIBUS V0 Slave using Siemens SPC3 chipset

Freeze Mode

Sync Mode

Auto Baud Setting

Configurable Parameters

PROFIBUS Node Address: 1 to 125

Data byte swapping

Action on loss of PROFIBUS connection

Comm Fail Timeout Multiplier

Status Data location in Internal Database


RIO Protocol Specification


The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.


Protocol Specifications

The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.

Software Configurable Parameters

Rack Number Addressing

0 to 63

Rack Size

¼-rack, ½-rack, ¾-rack and full rack

Starting Group

0,2,4,6

Last Rack

Yes or No

Baud Rate

57.6K, 115K, 230K

Functional Specifications

Supports block-transfers of data with scanner

Supports I/O data movement. Amount determined by rack size configuration

BTW Command - up to 64 words

BTR Command - up to 63 words

Physical Connection

Remote I/O connector

Standard 3-screw termination connector


证书

ATEX Letter of Conformity 114.27 kB 最后修改 2022.05.12
CB Safety 35.78 kB 最后修改 2022.04.27
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16