The ProLinx Modbus TCP/IP to DH-485 Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DH-485-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a DH-485 device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The DH-485-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a DH-485 device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
This area is used to store error codes, counters, and port status information for each port.
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Specification |
Description |
Power Supply |
24 VDC nominal |
Current Load |
500 mA max @ 32 VDC max |
Operating Temperature |
-4° F to 122° F (-20° C to 50° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Relative Humidity |
5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
MNET DH485 Datasheet | 79.44 kB | 最后修改 2010.04.26 |
MNET Protocol Manual | 631.11 kB | 最后修改 2012.02.16 |
DH485 Driver Manual | 1.11 MB | 最后修改 2009.12.10 |
ProSoft Configuration Builder (PCB) | ||
LifeCycle Letter 5201-MNET-DH485 | 113.79 kB | 最后修改 2023.07.31 |
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server |
|
General |
Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000. |
Configurable Parameters |
Module IP Address |
Modbus TCP/IP Client |
|
General |
Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) |
Configurable parameters |
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer |
Command List |
Up to 100 fully configurable commands on the Client port |
The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information |
|
Error Checking |
BCC and CRC |
Communication Parameters |
Local Station ID: 0 to 31 |
DH-485 Slave Mode
In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode
In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master |
|
Command List |
Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count |
Polling of command list |
User configurable polling of commands, including disabled, continuous and on change of data (write only) |