      网关  >  DF1 Master/Slave to HART2 Multi-drop Gateway
      Find a Distributor Request Pricing
      5127-Serial-HART

      DF1 Master/Slave to HART2 Multi-drop Gateway

      5127-DFCM-HART2

      Discontinued: No new product for sale. More Info

      The ProLinx DF1 Master/Slave to HART Multi-drop Gateway creates a powerful connection between devices on a DF1 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight HART channels.

      The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.

      The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.

      • 特性 优势
      • 应用程序
      • 规格
      • 硬件
      • 下载
      • 协议
      • 视频
      • 证书

      特性 优势

      Applications

      The DFCM-HART gateways are the ideal solution for many applications where DF1 connectivity can be used to integrate Hart devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Hart device support, the module provides a very powerful interface to the many Hart devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

      应用程序

      The DFCM-HART modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate HART devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Hart device support, the module provides a very powerful interface to the many HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

      规格

      Internal Database

      The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

      The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

      Application Data Area

      The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

      Status Data Area

      This area is used to store error codes, counters, and port status information for each port.

      Configuration Data Area

      This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

      硬件

      Specification

      Description

      Power Supply

      24 VDC nominal
      18 to 32 VDC allowed
      Positive, Negative, GND Terminals
      2.5 mm screwdriver blade

      Current Load

      500 mA max @ 32 VDC max

      Operating Temperature

      -4° F to 122° F (-20° C to 50° C)

      Storage Temperature

      -40° F to 185° F (-40° C to 85° C)

      Relative Humidity

      5% to 95% (without condensation)

      Dimensions

      Standard:
      5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)

      Extended:
       5.20 in H x 2.73 in W x 4.52 in D (13.2 cm x 6.934 cm x 11.48 cm)

      LED Indicators

      Power and Module Status
      Application Status
      HART Channel Activity (Green)

      (Ethernet-equiped Gateways Only)
      Ethernet Link
      Ethernet Activity

      Configuration Serial Port

      DB-9M RS-232 only
      No hardware handshaking

      Ethernet Port (Ethernet modules only)

      RJ45 Connector

      Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

      Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

      HART Interface

      Four (4) HART Multi-drop channels

      Screw terminals for each channel

      24 VDC power supply
      (third-party, not supplied with the gateway)

      Must have sufficient current capacity to supply all loop-powered HART devices

      Screw terminals for 24 VDC available on HART connector, supplied with the gateway, for loop-powered configurations

      Shipped with Each Unit

      Mini-DIN to DB-9M serial cables
      4 ft RS-232 configuration cable
      2.5 mm screwdriver
      CD (docs and Configuration utility)
      RS232-to-RS422/RS485 Screw Terminal Adapter(s) (Serial Gateways Only)
      HART Terminal Block connector

      下载

      ProSoft Configuration Builder (PCB)
      DFCM HART Datasheet 63.39 kB 最后修改 2014.11.07
      DFCM Protocol Manual 866.04 kB 最后修改 2012.02.16
      HART Driver Manual 922.47 kB 最后修改 2017.09.15

      协议

      DFCM Protocol Specification


      The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.


      Protocol Specifications

      The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).

      General Parameters

      Communication parameters

      Local Station ID: 0 to 254
      Ports 1 to 3 Baud Rate: 110 to 115K baud
      Stop Bits: 1
      Data Size: 8 bits
      Parity: None, Even, Odd
      RTS Timing delays: 0 to 65535 milliseconds

      Error Checking

      BCC and CRC

      Miscellaneous

      Full hardware handshaking control, providing radio, smart modem and multi-drop support
      Floating point data supported

      DF1 Master Protocol Specifications

      The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.

      DF1 Master Driver

      DF1 Modes

      Full-Duplex - Master (Module generates commands)

      Half-Duplex - Polling

      Command List

      Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count

      Polling of Command List

      User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

      DF1 Slave Protocol Specifications

      The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.

      DF1 Slave Driver

      DF1 Modes

      Full Duplex - Slave (not peer mode)
      Half Duplex - Polled

      Configurable parameters per slave port

      Data Table File Start (File N[x] 0 to 999)
      Data Table File Size (1 to 1000 words)
      Data Table location in database (0 to 3999)


      HART Protocol Specification


      The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.


      Protocol Specifications

      The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

      The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

      General Parameters

      Communication parameters

      Number of HART Preambles: 2 to 50

      Enable Handheld: Y or N

      Primary Master: Y or N

      Configurable Parameters per Channel

      Auto-Poll Enable, Short / Long Address Retries, Retries After Error

      Poll Time After Error, Number of Commands, Slave List Error Pointer

      HART Driver

      Command List

      Up to 100 fully configurable commands per channel

      Polling of command list

      User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

      HART® is a registered trademark of the HART Communication Foundation


      视频

      Data Organization in ProSoft Modules and Gateways

      Guide to bit-level data addressing in ProSoft Modbus modules

      Guide to 32-bit data types in ProSoft Modbus modules

      证书

      CB Safety 35.78 kB 最后修改 2022.04.27
      UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
      UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16

Solutions

  • Amusement
  • Automated Material Handling
  • 汽车解决方案
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water / Wastewater
$(document).ready(function(){ $('.popup-youtube, .popup-vimeo, .popup-gmaps').magnificPopup({ disableOn: 700, type: 'iframe', mainClass: 'mfp-fade', removalDelay: 160, preloader: false, fixedContentPos: false }); //pagelayout banner? if($('.banner-image') !== 'undefined' ){ var banner_image_src = $('.banner-image img').attr('src'); $('.banner-image').hide(); $('.banner-page-title').css('background-image', 'url(' + banner_image_src + ')'); $('.banner-page-title').css('background-repeat', 'no-repeat'); } //if( $('.analytics-file-download' ) !== 'undefined' ) { // $('.analytics-file-download' ).click(function(){ // var action = $( this ).attr( 'href' ); // var label = $( this ).attr( '_gaq-label' ); // var category = $( this ).attr( '_gaq-category' ); // return ga('send', 'event', category, action, label); // }); //} //initialize search? $("#div_search_field input").focusin(function(){ $(this).css("color", "#000000"); }); var initialSearch = $('form.search input.text').attr("value"); var currentSearch = ""; $('form.search input.text').focusin(function(){ currentSearch = $('form.search input.text').attr("value"); if( currentSearch == initialSearch ) { $('form.search input.text').attr("value",""); } }); }); //Homepage slideshow if( $('#slider') !== 'undefined' ) { $('#slider').nivoSlider({ pauseTime: 7000 // time for a slide to show, in milliseconds; subtract 2 seconds for actual time due to transition time }); } //eZ Live Viewer //(function(){var ff=document.createElement('script');ff.type='text/javascript';ff.async=true;ff.src=('https:'==document.location.protocol?'https':'http')+'://liveviewer.ez.no/statjs/sst-118-973155090/stat.js';var s=document.getElementsByTagName('script')[0];s.parentNode.insertBefore(ff,s);})(); // Pardot integration piAId = '281892'; piCId = '1546'; (function() { function async_load(){ var s = document.createElement('script'); s.type = 'text/javascript'; s.src = ('https:' == document.location.protocol ? 'https://pi' : 'http://cdn') + '.pardot.com/pd.js'; var c = document.getElementsByTagName('script')[0]; c.parentNode.insertBefore(s, c); } if(window.attachEvent) { window.attachEvent('onload', async_load); } else { window.addEventListener('load', async_load, false); } })();