5201-Ethernet

Modbus TCP/IP to GE Ethernet Global Data Gateway

5201-MNET-EGD

Discontinued: No new product for sale. More Info

The ProLinx Modbus TCP/IP to GE Ethernet Global Data Gateway creates a powerful connection between Modbus TCP/IP and GE Ethernet Global Data networks.The module provides one Ethernet port

The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Serverconnections.

The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged betweendevices and/or networks using a shared commondatabase. This common database provides the"backbone" communications for various field devices using different networks.

特性 优势

Applications

The MNET-EGD modules are the ideal solution for themany applications where Modbus TCP/IP connectivitycan be used to integrate GE Ethernet Global Datadevices into a system. The Modbus TCP/IP driver is apowerful module designed with both Client and Serversupport, enabling easy connection to other ModbusTCP/IP devices (Modicon processors and many others).In combination with the GE Ethernet Global Data devicesupport, the module provides a powerful interface to themany Modbus TCP/IP devices which are in use in theindustrial marketplace today. Applications for the moduleare found in most industries, especially Manufacturing,Oil and Gas, Electrical Power and Food Processing.

应用程序

The MNET-EGD modules are the ideal solution for themany applications where Modbus TCP/IP connectivitycan be used to integrate GE Ethernet Global Datadevices into a system. The Modbus TCP/IP driver is apowerful module designed with both Client and Serversupport, enabling easy connection to other ModbusTCP/IP devices (Modicon processors and many others).In combination with the GE Ethernet Global Data devicesupport, the module provides a powerful interface to themany Modbus TCP/IP devices which are in use in theindustrial marketplace today. Applications for the moduleare found in most industries, especially Manufacturing,Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

下载

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13
MNET EGD Datasheet 204.91 kB 最后修改 2014.05.06
MNET Protocol Manual 631.11 kB 最后修改 2012.02.16
EGD Protocol Manual 901.86 kB 最后修改 2016.08.05

协议

EGD Protocol Specification


The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.


Protocol Specifications

GE Fanuc Automation and GE Drive Systems developed an Ethernet Global Data, or EGD, exchange for PLC and computer data in 1998. GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume.

The module supports the following functions specified in the EGD protocol:

Code

Description

3

Retrieve Configuration Request (example provided)

4

Retrieve Configuration Response (example provided)

7

Summary Request

8

Summary Response

9

Capabilities Request

10

Capabilities Request

15

Statistics Request

16

Statistics Response

18

Command NAK

32

Read Request

33

Read Response

34

Write Request

35

Write Response

36

Masked Write Request

37

Masked Write Response


MNET Protocol Specification


The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.


Protocol Specifications

The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.

Modbus TCP/IP Server

General

Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.

Configurable Parameters

Module IP Address
Modbus address offsetting

Modbus TCP/IP Client

General

Actively reads and writes data with Modbus TCP/IP compatible devices.

One client connection (up to 100 servers/devices with 100 commands)

Configurable parameters

Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer

Command List

Up to 100 fully configurable commands on the Client port


证书

ATEX Letter of Conformity 114.27 kB 最后修改 2022.05.12
CB Safety 35.78 kB 最后修改 2022.04.27
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16