LP-24002 Lightning Protector

RadioLinx Lightning Protection

LP-24002 / LP-24003

RadioLinx Lightning Protection is designed to provide protection for broadband wireless, Wi-Fi, and WLAN systems with low RF power and excellent protection for less exposed subscriber units.

特性 优势

LP-24002

The LP-24002 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure. The connectors are standard N jack connector to standard N jack BH connector. The bulkhead fitting can be connected to any standard N type connector extension cable.

LP-24003

The LP-24003 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure and connecting to a N plug barrel adapter. This can then connect to any antenna with a standard N type connector.

应用程序

RadioLinx Lightning Protection is designed to protect the radio in the event of a lightning strike. A minimum 6 gauge copper wire should be used to connect the lightning protection to earth ground.

硬件

Hardware Specifications

Surge Capabilities

IEC 1000-4-5, 8/20µs @ 10kA

Frequency Range

2.0 to 6.0 GHz

Return Loss

> 20 dB

Insertion Loss

≤ 0.2 dB

RF Power

10W

Temperature Operating/Storage

-40°to 85°C

Relative Humidity

0 to 100% condensing

Surge Throughput Energy

≤ 0.5µJ (6kV/3kA 8/20µs)

Peak Let-Through Voltage

± 3V (6kV/3kA 8/20µs)

下载

Lightning Protection Datasheet 113.56 kB 最后修改 2009.12.14