5205-Ethernet-PDPS

DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway

5205-DNPSNET-PDPS

Discontinued: No new product for sale. More Info

The ProLinx DNP over Ethernet to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP over Ethernet network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port.

The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.

The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.

特性 优势

Applications

The DNPSNET-PDPS modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP master device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

应用程序

The DNPSNET-PDPS modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP master device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

规格

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

硬件

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

下载

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114.23 kB 最后修改 2023.11.13
DNPSNET PDPS Datasheet 81.03 kB 最后修改 2010.04.26
DNPSNET Protocol Manual 1.03 MB 最后修改 2015.04.27
ProLinx GSD File 398.03 kB 最后修改 2010.05.11

协议

DNPSNET Protocol Specification


The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.


Protocol Specifications

The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.

General Parameters

Internal Database

Binary Inputs: 8000 points (500 words)

Analog Inputs: 500 points

Counters: 250 (500 words)

Binary Outputs: 2000 points (125 words)

Analog Outputs: 500 points

DNP Mode

DNP 3.0 Slave - Level 2

DNP Server

Service Port

20000

Protocols

TCP (1 connection) and UDP

Node address

0 to 65534 (software selectable)

The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.


PDPS Protocol Specification


The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.


Protocol Specifications

The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.

General Parameters

GSD File

PRLX05A5.GSD

Downloadable from ProSoft Technology web site

PROFIBUS Specifications

Communication parameters

Baud Rate: 9.6 kbps to 12 Mbps

Supported I/O length

244 bytes Input data

244 bytes Output data

400 bytes total

Supported PROFIBUS DP features

PROFIBUS V0 Slave using Siemens SPC3 chipset

Freeze Mode

Sync Mode

Auto Baud Setting

Configurable Parameters

PROFIBUS Node Address: 1 to 125

Data byte swapping

Action on loss of PROFIBUS connection

Comm Fail Timeout Multiplier

Status Data location in Internal Database


证书

CB Safety 35.78 kB 最后修改 2022.04.27
Korean KC Registration 851.60 kB 最后修改 2020.03.13
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB 最后修改 2020.07.10
UL/cUL; Class 1, Div 2 1.08 MB 最后修改 2020.03.31
UL Certificate of Compliance - Canada 1.10 MB 最后修改 2022.11.16